Ersemus UAB

Engineering consultancy and services


Created to meet chalenges

Ersemus UAB was created in challenging times to meet Customers demand in sophisticated environment. Our main mission - to help you to reach any ambitious goal.

Taking in advantage of accumulated experience in logistic, mechanics, maintenance and other  engineering-related fields we can help you in different tasks.

our services includes but not limited:

- management and budgeting of projects;

- maintenance of technical objects;

- providing a "flying service teams" for various jobs;

- providing and installation of emergency, continous and mobile energy sources up to 8 MW.

- supply, installation and maintenance of diesel generator sets



Diesel generator sets for sell or rent in stock

For other modifications, power, special requirements and other please ask

 

Rezervinis dyzelinis trifazis elektros generatorius IV-110 Rezervinis dyzelinis generatorius IV-110

 

Diesel generator IV-110, 110 kVA, stand-by, silent canopy

 Engine:
VOLVO PENTA TAD531GE
Power PRP/LTP - 88/98 Kw
Cylinders - 4
Cylinder capacity - 4,76 ltr.

DiameterxStroke 108x130
Compression ratio - 18
Cooling system - liquid
Injection - direct
Suction - turbocharged and intercooler
Rpm regulation - mechanical
Fly wheel coupling - 3-11.5
Oil capacity - 13 ltr.
Oil consumption 0,41 %
Min. oil pressure alarm - 2 bar.
Electrical system - 12 Vdc, battery 120Ah, engine start-up 3,1 kW Alternator:
L
EROY - SOMER TAL044-D
400/230V 50Hz 3 phase
Power PRP/LTP - 100/110 kVA
No. poles - 4
Voltage regulator - AREP + R180
No. wires - 6
Insulation - H
Efficiency Alt. 100% - 90,8
Xd - 341%
X'd - 14,7
X - 8
Degree of protection - IP23 

Other data:
Fuel consumption - 50% power - 12 ltr./hr., 75% power - 17 ltr./hr. , 100% power - 23 ltr./hr.
Fuel tank - 240 ltr.
Noise level @ 7 mtr. - 70 +/-2 dB(A)
Dimensions LxWxH - 2990x1140x1933 mm.
Genset comply EU legislation and directives 2006/42/EC on machinery safety, 2005/88/EC on noise emissions, 2014/30/UE on electromagnetic compability, 2014/3/UE on electrical safety.
Warranty - 24 months or 500 hr/year limit         


Dyzelinis trifazis elektros generatorius su priekaba Dyzelinis generatorius IIR-066 su priekaba

 

Diesel generator IIR-066, 66 kVA, rental, silent canopy, on trailer

Engine:
FPT/IVECO N45SM1A
Power PRP/LTP - 53/59 Kw
Cylinders - 4
Cylinder capacity - 4,50 ltr.
DiameterxStroke 104x132
Compression ratio - 17,5
Cooling system - liquid
Injection - direct
Suction - turbocharged 
Rpm regulation - mechanical
Fly wheel coupling - 3-11.5
Oil capacity - 12,8 ltr.
Oil consumption 0,1 %
Min. oil pressure alarm - 3 bar.
Electrical system - 12 Vdc, battery 90Ah, engine start-up 3,0 kW                                                                                   
Alternator:
LEROY - SOMER TAL042-H
400/230V 50Hz 3 phase
Power PRP/LTP - 60/66 kVA
No. poles - 4
Voltage regulator - AREP + R180
No. wires - 6
Insulation - H
Efficiency Alt. 100% - 89,9

Xd - 303%

X'd - 14,7

X - 7,3
Degree of protection - IP23 
 Other data:
Fuel consumption - 50% power - 7 ltr./hr., 75% power - 10,2 ltr./hr., 100% power - 13,7 ltr./hr.
Fuel tank - 250 ltr.
Noise level @ 7 mtr. - 64 +/-2 dB(A)
Dimensions LxWxH - 2540x1140x1647 mm.
Genset comply EU legislation and directives 2006/42/EC on machinery safety, 2005/88/EC on noise emissions, 2014/30/UE on electromagnetic compability, 2014/3/UE on electrical safety.
Warranty - 12 months, no limit of run-hours

 

 

Rezervinis dyzelinis trifazis elektros generatorius AI-140 Rezervinis dyzelinis generatorius AI-140


Diesel generator AI-140, 138 kVA, stand-by, open 

Engine:
FPT/IVECO N67SM1
Power PRP/LTP - 110/121 Kw
Cylinders - 6
Cylinder capacity - 6,7 ltr.
DiameterxStroke 104x132
Compression ratio - 17,5
Cooling system - liquid
Injection - direct
Suction - turbocharged
Rpm regulation - mechanical
Fly wheel coupling - 3-11.5
Oil capacity - 17,2 ltr.
Oil consumption 0,1 %
Min. oil pressure alarm - 3,5 bar.
Electrical system - 12 Vdc, battery 120Ah, engine start-up 3 kW
Alternator:
LEROY - SOMER TAL044-H
400/230V 50Hz 3 phase
Power PRP/LTP - 135/150 kVA
No. poles - 4
Voltage regulator - AREP + R180
No. wires - 6
Insulation - H
Efficiency Alt. 100% - 92,1
Xd - 361%
X'd - 16,7
X - 10
Degree of protection - IP23
Other data:
Fuel consumption - 50% power - 15,8 ltr./hr., 75% power - 24,1 ltr./hr. , 100% power - 29,3 ltr./hr.
Fuel tank - 360 ltr.
Dimensions LxWxH - 2500x1035x1757 mm.
Genset comply EU legislation and directives 2006/42/EC on machinery safety, 2005/88/EC on noise emissions, 2014/30/UE on electromagnetic compability, 2014/3/UE on electrical safety.
Warranty - 12 months, no limit of run-hours

 

 

Dyzelinis trifazis elektros generatorius Dyzelinis generatorius IIR-044


Diesel generator IIR-044, 45 kVA, rental, silent canopy

Engine:
FPT/IVECO N45AM1A
Power PRP/LTP - 41/45 Kw
Cylinders - 4
Cylinder capacity - 4,5 ltr.
DiameterxStroke 104x132
Compression ratio - 17,5
Cooling system - liquid
Injection - direct
Suction - natural
Rpm regulation - mechanical
Oil capacity - 12,8 ltr.
Oil consumption 0,1 %
Electrical system - 12 Vdc, battery 90Ah, engine start-up 3 kW 
Alternator:

 LEROY - SOMER TAL044-H

400/230V 50Hz 3 phase
Power PRP/LTP - 40/45 kVA
No. poles - 4
Voltage regulator - AREP + R180
No. wires - 6
Insulation - H
Efficiency Alt. 100% - 88,9
Xd - 281%
X'd - 14,8
X - 7,4
Degree of protection - IP23
Other data:
Fuel consumption - 50% power - 6,4 ltr./hr., 75% power - 9,2 ltr./hr., 100% power - 11,3 ltr./hr.
Fuel tank - 250 ltr.
Dimensions LxWxH - 2540x1140x1647 mm.
Genset comply EU legislation and directives 2006/42/EC on machinery safety, 2005/88/EC on noise emissions, 2014/30/UE on electromagnetic compability, 2014/3/UE on electrical safety.
Warranty - 12 months, no limit of run-hours